[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
 
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
This article is specific to flow-through [[Stormwater planters| stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
+
This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
 
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
 
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
   Line 12: Line 12:  
|-
 
|-
 
| Ponding (''d<sub>p</sub>'')
 
| Ponding (''d<sub>p</sub>'')
| ≥ 300 mm
+
| 150 to 450 mm
 
| 1
 
| 1
 
|-
 
|-
Line 19: Line 19:  
|  
 
|  
 
* 0.7 for wood based
 
* 0.7 for wood based
* 0.4 for aggregate
+
* 0.4 for stone
 
|-
 
|-
 
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'')
 
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'')
 
|  
 
|  
 
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
 
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
* 600 mm to support flowering [[perennials]] and decorative [[grasses]]
+
* 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]]
 
* 1000 mm to support [[trees]]
 
* 1000 mm to support [[trees]]
| 0.35
+
|
 +
* 0.35 for Blend A - Drainage rate priority;
 +
* 0.4 for Blend B - Water quality treatment priority
 
|-
 
|-
 