Line 1: Line 1:  
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
 
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
This article is specific to [[Flow-through stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
+
This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
 
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
 
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
{{TOClimit|2}}
+
 
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.   
+
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the [[Pipe| pipe]] play critical roles for flow control.   
    
{| class="wikitable"
 
{| class="wikitable"
Line 9: Line 9:  
! Component
 
! Component
 
! Recommended depth (with underdrain pipe)
 
! Recommended depth (with underdrain pipe)
! Typical void ratio (''V<sub>R</sub>'')
+
! Typical porosity (''n'')
 
|-
 
|-
 
| Ponding (''d<sub>p</sub>'')
 
| Ponding (''d<sub>p</sub>'')
| ≥ 300 mm
+
| 150 to 450 mm
 
| 1
 
| 1
 
|-
 
|-
Line 19: Line 19:  
|  
 
|  
 
* 0.7 for wood based
 
* 0.7 for wood based
* 0.4 for aggregate
+
* 0.4 for stone
 
|-
 
|-
| [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'')
+
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'')
 
|  
 
|  
 
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
 
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
* 600 mm to support flowering [[perennials]] and decorative [[grasses]]
+
* 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]]
 
* 1000 mm to support [[trees]]
 
* 1000 mm to support [[trees]]
| 0.3
+
|
 +
* 0.35 for Blend A - Drainage rate priority;
 +
* 0.4 for Blend B - Water quality treatment priority
 
|-
 
|-
   
| Pipe diameter reservoir
 
| Pipe diameter reservoir
| Is equal to underdrain pipe diameter
+
| Is equal to underdrain [[pipe]] diameter
 
| 0.4  
 
| 0.4  
 
|-
 
|-
| Pipe bedding (''d<sub>b</sub>'')
+
| [[Choker course|Pipe bedding]] (''d<sub>b</sub>'')
 
| 50 mm (although commonly omitted altogether).  
 
| 50 mm (although commonly omitted altogether).  
 
| 0.4
 
| 0.4
 
|}
 
|}
  −
  −
==Calculate the maximum overall depth==
  −
*Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above.
  −
*Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth. 
  −
*Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s</sub>''):
  −
<math>d_{s}=f'\times38.4</math>
  −
{{Plainlist|1=Where:
  −
*''f''' = Design infiltration rate in mm/hr, and
  −
*38.4 comes from multiplying desired drainage time of 96 hours by void ratio of 0.4}}
  −
  −
===Additional step for system without underdrain===
  −
*Step 4: Determine maximum permissible ponding depth (''d<sub>p</sub>''):
  −
<math>d_{p}=f'\times19.2</math>
  −
{{Plainlist|1=Where:
  −
*''f''' = Design infiltration rate in mm/hr, and
  −
*19.2 comes from multiplying desired drainage time of 48 hours by void ratio of 0.4. Note that conceptually the drainage of the ponded area is limited by ex-filtration at the base of the practice.}}
  −
* Step 5: Sum total depth of bioretention, and compare to available space above water table and bedrock. Adjust if necessary.
  −
  −
==Calculate the remaining dimensions==
  −
* Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
  −
* Step 7: Calculate the required total storage (m<sup>3</sup>):
  −
<math>Storage=RVC_T\times A_c\times C\times 0.1</math>
  −
{{Plainlist|1=Where:
  −
*''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
  −
*''A<sub>c</sub>'' is the catchment area (Ha),
  −
*''C'' is the runoff coefficient of the catchment area, and
  −
* 0.1 is the units correction between m<sup>3</sup> and mm.Ha.}}
  −
* Step 8. Divide required storage (m<sup>3</sup>) by the 1 dimensional storage (in m) to find the required footprint area (''A<sub>p</sub>'') for the bioretention in m<sup>2</sup>.
  −
* Step 9. Calculate the peak flow rate (''Q<sub>p</sub>'', in L/s) through the filter media:
  −
----
 