| |'''Pervious concrete''' | |'''Pervious concrete''' | ||
| | | | | ||
| − | * 28 day compressive strength = 5.5 to 20 MPa  | + | * NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles. | 
| − | *  | + | * 28 day compressive strength = 5.5 to 20 MPa.  | 
| − | * Permeability = 900  | + | * Porosity between 14% to 31%. | 
| − | |Thickness will range from 100 mm - 150 mm depending on the expected loads | + | * Permeability = 900 to 21,500 mm/hr. | 
| + | * Proprietary pre-cast slabs meeting required specifications are also available. | ||
| + | |Thickness will range from 100 mm - 150 mm depending on the expected loads. | ||
| |- | |- | ||
| |'''Porous asphalt''' | |'''Porous asphalt''' | ||
| | | | | ||
| − | *  | + | * Open-graded asphalt mix with a minimum porosity of 16%.  | 
| − | *  | + | * Polymers can be added to provide additional strength to heavy loads. | 
| − | |Thickness will range from 50 mm - 100 mm depending on the expected loads | + | *The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt. | 
| + | |Thickness will range from 50 mm - 100 mm depending on the expected loads. | ||
| |- | |- | ||
| − | |'''Permeable  | + | |'''Permeable Interlocking Pacements''' | 
| | | | | ||
| − | *ASTM No. 8(5 mm dia) crushed aggregate is recommended for fill material in the paver  | + | *Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).  | 
| − | * | + | *Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area.  | 
| − | + | *ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB).   | |
| − | + | *For narrow joint pavers, a smaller sized aggregate may be used.  Narrow joints are required where pavement must be AODA compliant. | |
| | | | | ||
| *For vehicle applications the minimum paver thickness is 80 mm | *For vehicle applications the minimum paver thickness is 80 mm | ||
| − | *For pedestrian applications is 60 mm and joint widths should be no greater than 15 mm.   | + | *For pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm.   | 
| |} | |} | ||
Revision as of 14:05, 5 August 2020
| Material | Specification | Quantity | 
|---|---|---|
| Pervious concrete | 
 | Thickness will range from 100 mm - 150 mm depending on the expected loads. | 
| Porous asphalt | 
 | Thickness will range from 50 mm - 100 mm depending on the expected loads. | 
| Permeable Interlocking Pacements | 
 | 
 |