Difference between revisions of "Rainwater harvesting: TTT"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) |
Jenny Hill (talk | contribs) |
||
| Line 27: | Line 27: | ||
#Maximum depth (m) | #Maximum depth (m) | ||
#Initial water depth (m) | #Initial water depth (m) | ||
| − | + | The Curves table is designed to accommodate ponds of roughly conical dimensions. A rainwater cistern is usually cuboid or cylindrical in shape, so that the area (m<sup>2</sup>) will remain the same throughout the depth. | |
|} | |} | ||
[[category:modeling]] | [[category:modeling]] | ||
Revision as of 21:05, 7 September 2017
Once the size of cistern has been determined, it can easily be modeled in many open source and proprietary applications. For planning purposes, a RWH system could be integrated into a site plan using STEP's Treatment Train Tool. This tool provides a graphical user interface and simplified inputs on the EPA SWMM model. It is free to download, click image above. In a typical configuration:
| Catchment (roof) | 100% impervious |
| The rainwater harvesting system would be a 'Storage' Element with the following properties: | |
| Storage type | No removal |
| ? | Lined |
| Underlying soil | Doesn't matter |
| Evaporation factor | 0 |
| Suction head (mm) | 0 |
| Saturated conductivity (mm/hr) | 0 |
| Initial soil moisture deficit (fraction) | 0 |
The dimensions of the rainwater cistern can be placed into the fields:
The Curves table is designed to accommodate ponds of roughly conical dimensions. A rainwater cistern is usually cuboid or cylindrical in shape, so that the area (m2) will remain the same throughout the depth. | |