| Line 41: | 
Line 41: | 
|   | {{Clickable button|[[Media:Infiltration Sizing.xlsx|Download .xlsx calculation tool]]}}  |   | {{Clickable button|[[Media:Infiltration Sizing.xlsx|Download .xlsx calculation tool]]}}  | 
|   |  |   |  | 
| − | ==One dimensional infiltration==  | + | ==To calculate the required depth, where the area of the facility is constrained (1D)==  | 
| − | To calculate the required depth, where the area of the facility is constrained:  |   | 
|   | <math>d=\frac{D\left[\left( \frac{I}{P} \right )i-q \right]}{n}</math>  |   | <math>d=\frac{D\left[\left( \frac{I}{P} \right )i-q \right]}{n}</math>  | 
|   |  |   |  | 
| − | To calculate the require facility area or footprint where the depth is constrained:  | + | ==To calculate the require facility area or footprint where the depth is constrained (1D)==  | 
|   | <math>P=\frac{IiD}{nd+qD}</math>  |   | <math>P=\frac{IiD}{nd+qD}</math>  | 
|   |  |   |  | 
| − | <h3>Drawdown time</h3>
  | + | ==Infiltration of surface ponding time==  | 
|   | The following equation assumes that infiltration occurs primarily through the footprint of the facility.  |   | The following equation assumes that infiltration occurs primarily through the footprint of the facility.  | 
| − | It is best applied to calculate the limited duration ponding on the surface of [[bioretention cells]], [[bioswales]] and [[enhanced grass swales]].  | + | It is best applied to calculate the limited duration ponding on the surface of [[bioretention cells]], [[bioswales]] and [[enhanced grass swales]].    | 
| − |    |   | 
| − |    |   | 
|   | To calculate the time (''t'') to fully drain the facility through the footprint area only:    |   | To calculate the time (''t'') to fully drain the facility through the footprint area only:    | 
| − | <math>t=\frac{nd}{q}</math>  | + | <math>t=\frac{nd}{K}</math>  | 
|   |  |   |  | 
|   | ==Three dimensional infiltration==  |   | ==Three dimensional infiltration==  |