|  | ==Calculate the maximum overall depth== |  | ==Calculate the maximum overall depth== | 
| − | *Step 1: Determine what the planting needs are and assign appropriate depth of media, using the table above. 
 |  | 
| − | *Step 2: Select an underdrain pipe diameter (typically 100 - 200 mm), assign this as an 'embedding' depth.  
 |  | 
| − | *Step 3: Calculate the maximum possible storage reservoir depth beneath the pipe (''d<sub>s</sub>''):
 |  | 
| − | <math>d_{s}=f'\times38.4</math>
 |  | 
| − | {{Plainlist|1=Where:
 |  | 
| − | *''f''' = Design infiltration rate in mm/hr, and
 |  | 
| − | *38.4 comes from multiplying desired drainage time of 96 hours by void ratio of 0.4}}
 |  | 
| − | 
 |  | 
| − | ===Additional step for system without underdrain===
 |  | 
| − | *Step 4: Determine maximum permissible ponding depth (''d<sub>p</sub>''):
 |  | 
| − | <math>d_{p}=f'\times19.2</math>
 |  | 
| − | {{Plainlist|1=Where:
 |  | 
| − | *''f''' = Design infiltration rate in mm/hr, and
 |  | 
| − | *19.2 comes from multiplying desired drainage time of 48 hours by void ratio of 0.4. Note that conceptually the drainage of the ponded area is limited by ex-filtration at the base of the practice.}}
 |  | 
| − | * Step 5: Sum total depth of bioretention, and compare to available space above water table and bedrock. Adjust if necessary.
 |  | 
| − | 
 |  | 
| − | ==Calculate the remaining dimensions==
 |  | 
| − | * Step 6: Multiply the depth of each separate component by the void ratio and then sum the total to find the 1 dimensional storage (in mm).
 |  | 
| − | * Step 7: Calculate the required total storage (m<sup>3</sup>):
 |  | 
| − | <math>Storage=RVC_T\times A_c\times C\times 0.1</math>
 |  | 
| − | {{Plainlist|1=Where:
 |  | 
| − | *''RVC<sub>T</sub>'' is the Runoff volume control target (mm),
 |  | 
| − | *''A<sub>c</sub>'' is the catchment area (Ha), 
 |  | 
| − | *''C'' is the runoff coefficient of the catchment area, and
 |  | 
| − | * 0.1 is the units correction between m<sup>3</sup> and mm.Ha.}}
 |  | 
| − | * Step 8. Divide required storage (m<sup>3</sup>) by the 1 dimensional storage (in m) to find the required footprint area (''A<sub>p</sub>'') for the bioretention in m<sup>2</sup>. 
 |  | 
| − | * Step 9. Calculate the peak flow rate (''Q<sub>p</sub>'', in L/s) through the filter media:
 |  | 
| − | ----
 |  |