Difference between revisions of "Permeable pavements: Specifications"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) m (Jenny Hill moved page Specifications to Permeable paving: Specifications without leaving a redirect) |
m (Sahlla Abbasi moved page Permeable paving: Specifications to Permeable pavements: Specifications: Updating terminology from permeable paving -> permeable pavements on all pages) |
||
| (4 intermediate revisions by 2 users not shown) | |||
| Line 6: | Line 6: | ||
!Quantity | !Quantity | ||
|- | |- | ||
| − | |'''Pervious | + | |'''Pervious concrete''' |
| | | | ||
| − | * 28 day compressive strength = 5.5 to 20 MPa | + | * NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles. |
| − | * | + | * 28 day compressive strength = 5.5 to 20 MPa. |
| − | * Permeability = 900 | + | * Porosity between 14% to 31%. |
| − | |Thickness will range from 100 mm - 150 mm depending on the expected loads | + | * Permeability = 900 to 21,500 mm/hr. |
| + | * Proprietary pre-cast slabs meeting required specifications are also available. | ||
| + | |Thickness will range from 100 mm - 150 mm depending on the expected loads. | ||
|- | |- | ||
| − | |'''Porous | + | |'''Porous asphalt''' |
| | | | ||
| − | * | + | * Open-graded asphalt mix with a minimum porosity of 16%. |
| − | * | + | * Polymers can be added to provide additional strength to heavy loads. |
| − | |Thickness will range from 50 mm - 100 mm depending on the expected loads | + | *The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt. |
| + | |Thickness will range from 50 mm - 100 mm depending on the expected loads. | ||
|- | |- | ||
| − | |'''Permeable | + | |'''Permeable Interlocking Pavements''' |
| | | | ||
| − | *ASTM No. 8(5 mm dia) | + | *Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States). |
| − | + | *Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area. | |
| − | * | + | *ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB). |
| − | + | *For narrow joint pavers, a smaller sized aggregate may be used. Narrow joints are required where pavement must be AODA compliant. | |
| | | | ||
*For vehicle applications the minimum paver thickness is 80 mm | *For vehicle applications the minimum paver thickness is 80 mm | ||
| − | *For pedestrian applications is 60 mm and | + | *For pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm. |
| − | | | + | |} |
Latest revision as of 14:42, 6 August 2020
| Material | Specification | Quantity |
|---|---|---|
| Pervious concrete |
|
Thickness will range from 100 mm - 150 mm depending on the expected loads. |
| Porous asphalt |
|
Thickness will range from 50 mm - 100 mm depending on the expected loads. |
| Permeable Interlocking Pavements |
|
|