| − | In [[bioretention]] systems a  | + | In [[bioretention]] systems a choker layer of ≥ 100 mm depth is the recommended method to prevent migration of finer [[filter media]] into the underlying [[Reservoir gravel|storage reservoir aggregate]]. | 
| − | These same mid sized granular materials are recommended for use in [[Stormwater planter]] underdrains.   | + | These same mid-sized granular materials are recommended for use in [[Stormwater planter]] underdrains and may be useful in the fine grading of foundations courses for [[permeable pavements]]. | 
| Suitable materials include: | Suitable materials include: | ||
| ;High performance bedding (HPB) | ;High performance bedding (HPB) | ||
| − | :Clean, angular aggregate screened to between 6  | + | :Clean, angular aggregate screened to between 6 and 10 mm. Widely available and designed specifically for drainage applications. Free from fines by definition.    | 
| ;HL 6 | ;HL 6 | ||
| − | :Is a clean, angular aggregate screened between 10  | + | :Is a clean, angular aggregate screened between 10 and 20 mm. Free from fines by definition.   | 
| ;Pea Gravel | ;Pea Gravel | ||
| − | :Rounded natural aggregate, screened between 5  | + | :Rounded natural aggregate, screened between 5 and 15 mm, and washed free from fines.   | 
| − | In most scenarios, a [[geotextiles|geotextile]] layer is unnecessary and  | + | In most scenarios, a [[geotextiles|geotextile]] layer is unnecessary and has been associated with rapid decline and [[Clogging#Filter fabric|clogging]] in some circumstances.   | 
| [[category: materials]] | [[category: materials]] | ||
Latest revision as of 14:05, 6 August 2020
In bioretention systems a choker layer of ≥ 100 mm depth is the recommended method to prevent migration of finer filter media into the underlying storage reservoir aggregate. These same mid-sized granular materials are recommended for use in Stormwater planter underdrains and may be useful in the fine grading of foundations courses for permeable pavements.
Suitable materials include:
- High performance bedding (HPB)
- Clean, angular aggregate screened to between 6 and 10 mm. Widely available and designed specifically for drainage applications. Free from fines by definition.
- HL 6
- Is a clean, angular aggregate screened between 10 and 20 mm. Free from fines by definition.
- Pea Gravel
- Rounded natural aggregate, screened between 5 and 15 mm, and washed free from fines.
In most scenarios, a geotextile layer is unnecessary and has been associated with rapid decline and clogging in some circumstances.