| Line 11: | 
Line 11: | 
|   | Infiltration practices are not recommended:  |   | Infiltration practices are not recommended:  | 
|   | <ol>  |   | <ol>  | 
| − | <li>Where the bedrock is within 1 m below the bottom of the proposed BMP.</li>  | + | <li>Where the bedrock is within 1 m below the bottom of the proposed BMP,</li>  | 
| − | <li>Where the seasonal high groundwater level comes within 1 m below the bottom of the proposed BMP. <br>Or in areas where increased infiltration will result in elevated groundwater levels, which can be demonstrated to damage critical utilities or private property. </li>  | + | <li>Where the seasonal high groundwater level comes within 1 m below the bottom of the proposed BMP,<br>Or in areas where increased infiltration will result in elevated groundwater levels, which can be demonstrated to damage critical utilities or private property,</li>  | 
| − | <li>Over swelling clays or unstable sub-soils</li>  | + | <li>Over swelling clays or unstable sub-soils,</li>  | 
| − | <li>Over contaminated soils or sites with high risk of contamination from onsite activities </li>  | + | <li>Over contaminated soils or sites with high risk of contamination from onsite activities, </li>  | 
| − | <li>In flood prone areas where the wastewater system is sensitive to groundwater conditions causing sewer backups, and where LID BMPs have been found to be ineffective. </li>  | + | <li>In flood prone areas where the wastewater system is sensitive to groundwater conditions causing sewer backups, and where LID BMPs have been found to be ineffective,</li>  | 
| − | <li>In areas where the ecology and natural hydrology are dependent upon surface water. </li>  | + | <li>In areas where the ecology and natural hydrology are dependent upon surface water,</li>  | 
|   | <li>Where prohibitions and/or restrictions exist per approved Source Protection Plans (see MOECC guidance).    |   | <li>Where prohibitions and/or restrictions exist per approved Source Protection Plans (see MOECC guidance).    | 
|   | </ol>  |   | </ol>  | 
|   | + | <br><p>  | 
|   | + | Infiltration can still be optimized over 'tight' soils with infiltration rates ≤ 15 mm/hr:  | 
|   | + | <li>[[Partially infiltrating bioretention]]</li></p>  | 
|   | <br>  |   | <br>  | 
|   | <p>Without infiltration, many LID design alternatives exist which can still capture and retain  stormwater:  |   | <p>Without infiltration, many LID design alternatives exist which can still capture and retain  stormwater:  | 
|   | <ul>  |   | <ul>  | 
| − | <li>[[Partially infiltrating bioretention]]</li>
  |   | 
|   | <li>[[Bioretention planters]]</li>  |   | <li>[[Bioretention planters]]</li>  | 
|   | <li>[[Rainwater harvesting]]</li>  |   | <li>[[Rainwater harvesting]]</li>  |