| Line 1: | Line 1: | 
|  | Manufacturers of perforated pipe are often able to provide the open area per meter length.    |  | Manufacturers of perforated pipe are often able to provide the open area per meter length.    | 
|  |  |  |  | 
| − | <math>Q_{max, p}=B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \sum d}</math> | + | <math>Q_{max, p}=L\times B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \sum d}</math> | 
|  | {{Plainlist|1=Where:<sub>d</sub>'' is the coefficient of discharge (0.61 for a sharp edged orifice),    |  | {{Plainlist|1=Where:<sub>d</sub>'' is the coefficient of discharge (0.61 for a sharp edged orifice),    | 
|  | + | *''L'' is the length of perforated pipe (m) | 
|  | *''B'' is the clogging factor (between 0.5 to calculate a for matured installation and 1 to calculate a new perfectly performing BMP),      |  | *''B'' is the clogging factor (between 0.5 to calculate a for matured installation and 1 to calculate a new perfectly performing BMP),      | 
|  | *''C<sub>d</sub>'' is the coefficient of discharge (usually 0.61 for the sharp edge created by relatively thin pipe walls),   |  | *''C<sub>d</sub>'' is the coefficient of discharge (usually 0.61 for the sharp edge created by relatively thin pipe walls),   | 
| Line 15: | Line 16: | 
|  | <math>\frac{0.008\ m \times 0.0015\ m\times6}{0.03\ m }= 0.0024\ m^{2}/m</math> |  | <math>\frac{0.008\ m \times 0.0015\ m\times6}{0.03\ m }= 0.0024\ m^{2}/m</math> | 
|  | Then: |  | Then: | 
| − | <math>Q_{max, p}=0.5\times 0.61\times 0.0024\ m^{2}/m\sqrt{2\cdot 9.81\ m/s^{2}\cdot \sum 1.1\ m}=0.0034\ m^{3}/s</math> | + | <math>Q_{max, p}=8\times 0.5\times 0.61\times 0.0024\ m^{2}/m\sqrt{2\cdot 9.81\ m/s^{2}\cdot \sum 1.1\ m}=0.0034\ m^{3}/s</math> | 
|  | #{3} |  | #{3} |