Difference between revisions of "Pretreatment"
Jenny Hill (talk | contribs) m (→External links) |
Jenny Hill (talk | contribs) |
||
| Line 30: | Line 30: | ||
!OGS Baffles | !OGS Baffles | ||
|Baffles slow flow, encouraging larger, heavier particles to drop out of the water column. A skimmer may also trap floating debris, oils and grease.||- | |Baffles slow flow, encouraging larger, heavier particles to drop out of the water column. A skimmer may also trap floating debris, oils and grease.||- | ||
| − | |[http://upstreamtechnologies.us/products/safl.shtml SAFL baffle] | + | | |
| + | *[http://upstreamtechnologies.us/products/safl.shtml SAFL baffle] | ||
|- | |- | ||
!Hydrodynamic OGS | !Hydrodynamic OGS | ||
|The shape causes rapidly flowing water to form a vortex which forces the larger, heavier particles are outwards and downwards into a lower chamber. Floating debris, oils and grease are trapped behind a baffle or in small tank area, towards the top of the main vortex chamber | |The shape causes rapidly flowing water to form a vortex which forces the larger, heavier particles are outwards and downwards into a lower chamber. Floating debris, oils and grease are trapped behind a baffle or in small tank area, towards the top of the main vortex chamber | ||
| − | |[http://www.conteches.com/Products/Stormwater-Management/Treatment/CDS.aspx CDS] | + | | |
| − | [https://www.hydro-int.com/en/products/downstream-defender Downstream defender] | + | *[http://www.conteches.com/Products/Stormwater-Management/Treatment/CDS.aspx CDS] |
| − | [http://nextstorm.ca/sdd/ SDD] | + | *[https://www.hydro-int.com/en/products/downstream-defender Downstream defender] |
| − | |[http://www.imbriumsystems.com/stormwater-treatment-solutions/stormceptor-systems Stormceptor] | + | *[http://nextstorm.ca/sdd/ SDD] |
| + | | | ||
| + | *[http://www.imbriumsystems.com/stormwater-treatment-solutions/stormceptor-systems Stormceptor] | ||
|- | |- | ||
!Cartridge filters | !Cartridge filters | ||
|Uses advanced membrane technology adopted from water treatment plants.||- | |Uses advanced membrane technology adopted from water treatment plants.||- | ||
| − | |[http://www.imbriumsystems.com/stormwater-treatment-solutions/jellyfish-filter Jellyfish filter] | + | | |
| + | *[http://www.imbriumsystems.com/stormwater-treatment-solutions/jellyfish-filter Jellyfish filter] | ||
|- | |- | ||
!Catchbasin inserts | !Catchbasin inserts | ||
|Great for improving water quality in retrofit situations | |Great for improving water quality in retrofit situations | ||
| − | |[http://www.cbshield.com/ CB Shield] | + | | |
| − | |[http://upstreamtechnologies.us/products/snout.shtml Snout] | + | *[http://www.cbshield.com/ CB Shield] |
| + | | | ||
| + | *[http://upstreamtechnologies.us/products/snout.shtml Snout] | ||
|} | |} | ||
Revision as of 21:31, 8 March 2018
Pretreatment devices may be constructed in close association association with one or more inlets. Different configurations of each exist to accommodate any design.
Overland sheet flow[edit]
The following pretreatements are recommended where sheet flow is being directed to a BMP (e.g. a bioretention cell) receiving flow from the edge of an impermeable surface such as an asphalt parking lot or a paved plaza:
A gravel diaphragm typically requires less setback between the catchment and the BMP. Where space permits, these three designs can be used in combination to even greater effect!
Concentrated overland flow[edit]
Where a curb cut, a disconnected downspout or a swale directs surface water to a point, increasing the flow rate, one or more of the following pretreatments should be considered:
- Forebays (well suited for bioretention cells)
- Sand filters (well suited for underground infiltration)
- Screens and racks
- Also see stone for erosion control at inlets.
Concentrated underground flow[edit]
This type of pretreatement is dominated by proprietary systems, some of which have undergone verification under the Environmental Technology Verification (ETV) program.
| Type | Description | ETV products | Other products (not verified) |
|---|---|---|---|
| OGS Baffles | Baffles slow flow, encouraging larger, heavier particles to drop out of the water column. A skimmer may also trap floating debris, oils and grease. | - | |
| Hydrodynamic OGS | The shape causes rapidly flowing water to form a vortex which forces the larger, heavier particles are outwards and downwards into a lower chamber. Floating debris, oils and grease are trapped behind a baffle or in small tank area, towards the top of the main vortex chamber | ||
| Cartridge filters | Uses advanced membrane technology adopted from water treatment plants. | - | |
| Catchbasin inserts | Great for improving water quality in retrofit situations |
External links[edit]
This article is particularly heavy on proprietary systems and information. Please inform us of any omissions or broken links using the box below: