| Line 41: | Line 41: | 
|  |  |  |  | 
|  | ==Materials checklist==   |  | ==Materials checklist==   | 
| − | #Verify that porous bituminous asphalt, if proposed, is specified on the plans as meeting the following specifications: [Section 4.2.4, 2] | + | #Verify that porous bituminous asphalt, if proposed, is specified on the plans as meeting the following specifications: | 
|  | ##Bituminous surface must be laid with a bituminous mix of 5.75% to 6% by weight dry aggregate. |  | ##Bituminous surface must be laid with a bituminous mix of 5.75% to 6% by weight dry aggregate. | 
|  | ##In accordance with American Society of Testing and Materials (ASTM) D6390, drain down of the binder must be no greater than 0.3%. |  | ##In accordance with American Society of Testing and Materials (ASTM) D6390, drain down of the binder must be no greater than 0.3%. | 
| Line 79: | Line 79: | 
|  |  |  |  | 
|  |  |  |  | 
| − | Verify that permeable paver and grid systems, if proposed, are specified on the plans as meeting the following specifications: [Section 4.2.4, 4] | + | Verify that permeable paver and grid systems, if proposed, are specified on the plans as meeting the following specifications:   | 
|  | #Permeable paver and grid systems must conform to manufacturer specifications. |  | #Permeable paver and grid systems must conform to manufacturer specifications. | 
|  | #The systems must have a minimum flow through rate of five inches per hour and a void percentage of no less than 10%. |  | #The systems must have a minimum flow through rate of five inches per hour and a void percentage of no less than 10%. | 
|  | #Gravel used in interlocking concrete pavers or plastic grid systems must be well-graded and washed to ensure permeability. |  | #Gravel used in interlocking concrete pavers or plastic grid systems must be well-graded and washed to ensure permeability. | 
| − | #Verify that stone designed for stormwater storage, if proposed, is specified on the plans as being uniformly graded, crushed, clean-washed stone and that it is noted that PWD defines “clean-washed” as having less than 0.5% wash loss, by mass, when tested per the AASHTO T-11 wash loss test. AASHTO No. 3 and No. 57 stone can meet this specification. [Section 4.2.4, 6a] | + | #Verify that stone designed for stormwater storage, if proposed, is specified on the plans as being uniformly graded, crushed, clean-washed stone and that it is noted that PWD defines “clean-washed” as having less than 0.5% wash loss, by mass, when tested per the AASHTO T-11 wash loss test. AASHTO No. 3 and No. 57 stone can meet this specification. | 
| − | #Verify that all aggregates used within a porous pavement system meets the following requirements: [Section 4.2.4, 6b] | + | #Verify that all aggregates used within a porous pavement system meets the following requirements:   | 
| − |   |  | 
|  | Maximum wash loss: 0.5% per AASHTO T-11 |  | Maximum wash loss: 0.5% per AASHTO T-11 | 
|  | Minimum durability index: 35 per ASTM D3744 |  | Minimum durability index: 35 per ASTM D3744 | 
|  | Maximum abrasion: 10% for 100 revolutions and 50% for 500 revolutions per ASTM C131 |  | Maximum abrasion: 10% for 100 revolutions and 50% for 500 revolutions per ASTM C131 | 
| − | Verify that all choker course aggregate meets the specifications of AASHTO No. 57 and meets the gradation listed in Table 4.2-3 of the Manual. [Section 4.2.4, 6c] | + | Verify that all choker course aggregate meets the specifications of AASHTO No. 57 and meets the gradation listed in Table 4.2-3 of the Manual. | 
| − | Verify that sand, if proposed, is specified on the plans to be AASHTO M-6 or ASTM C-33 sand and to have a grain size of 0.02 inches to 0.04 inches. [Section 4.2.4, 7] | + | Verify that sand, if proposed, is specified on the plans to be AASHTO M-6 or ASTM C-33 sand and to have a grain size of 0.02 inches to 0.04 inches.   | 
| − | Verify that storage chambers for porous pavement structural SMPs, if proposed, are specified on the plans as meeting the following specifications: [Section 4.2.4, 8] | + | Verify that storage chambers for porous pavement structural SMPs, if proposed, are specified on the plans as meeting the following specifications:   | 
|  | Pipe used within a subsurface infiltration SMP must be continuously perforated and have a smooth interior with a minimum inner diameter of four inches. |  | Pipe used within a subsurface infiltration SMP must be continuously perforated and have a smooth interior with a minimum inner diameter of four inches. | 
|  | High-density polyethylene (HDPE) pipe, if proposed, must meet the specifications of AASHTO M252, Type S or AASHTO M294, Type S. |  | High-density polyethylene (HDPE) pipe, if proposed, must meet the specifications of AASHTO M252, Type S or AASHTO M294, Type S. | 
| Line 101: | Line 100: | 
|  | UV Resistance after 500 hrs (ASTM-D4355): ≥ 70% |  | UV Resistance after 500 hrs (ASTM-D4355): ≥ 70% | 
|  | Heat-set or heat-calendared fabrics are not permitted |  | Heat-set or heat-calendared fabrics are not permitted | 
| − | Verify that underdrains, if proposed, are made of continuously perforated HDPE plastic piping with a smooth interior and a minimum inner diameter of four inches. HDPE pipe must be specified on the plans to meet the specifications of AASHTO M252, Type S or AASHTO M294, Type S. [Section 4.2.4, 10] | + | Verify that underdrains, if proposed, are made of continuously perforated HDPE plastic piping with a smooth interior and a minimum inner diameter of four inches. HDPE pipe must be specified on the plans to meet the specifications of AASHTO M252, Type S or AASHTO M294, Type S.   | 
| − | Verify that observation wells are specified on the plans as consisting of perforated plastic pipe with a minimum inner diameter of six inches. [Section 4.2.4, 12] | + | Verify that observation wells are specified on the plans as consisting of perforated plastic pipe with a minimum inner diameter of six inches. | 
| − | Verify that cleanouts are made of rigid material with a smooth interior having a minimum inner diameter of four inches. [Section 4.2.4, 13] | + | Verify that cleanouts are made of rigid material with a smooth interior having a minimum inner diameter of four inches. | 
|  |  |  |  | 
|  |  |  |  |