From LID SWM Planning and Design Guide
		
		
		
		
		Jump to navigation
		Jump to search
		
Specifications for pervious concrete, porous asphalt, and permeable pavers
| Material | Specification | Quantity | 
| Pervious concrete | 28 day compressive strength = 5.5 to 20 MPaVoid ratio = 14% - 31%Permeability = 900 - 21,500 mm/hr
 | Thickness will range from 100 mm - 150 mm depending on the expected loads | 
| Porous asphalt | open-graded asphalt mix with a minimum of 16 % air voidsPolymer can be added to provide additional strength to heavy loads
 | Thickness will range from 50 mm - 100 mm depending on the expected loads | 
| Permeable pavers | ASTM No. 8(5 mm dia) crushed aggregate is recommended for fill material in the paver openings.Pavers shall meet the minimum material and standard specification for precast concrete pavers.Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.Maximum allowable breakage of product is 5%
 | For vehicle applications the minimum paver thickness is 80 mmFor pedestrian applications is 60 mm and joint widths should be no greater than 15 mm.
 |