| Line 1: | Line 1: | 
|  | [[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] |  | [[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] | 
| − | This article is specific to flow-through [[Stormwater planters| stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br> | + | This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br> | 
|  | If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. |  | If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. | 
|  |  |  |  | 
| − | The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.    | + | The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the [[Pipe| pipe]] play critical roles for flow control.    | 
|  |  |  |  | 
|  | {| class="wikitable" |  | {| class="wikitable" | 
| Line 12: | Line 12: | 
|  | |- |  | |- | 
|  | | Ponding (''d<sub>p</sub>'') |  | | Ponding (''d<sub>p</sub>'') | 
| − | | ≥ 300 mm | + | | 150 to 450 mm | 
|  | | 1 |  | | 1 | 
|  | |- |  | |- | 
| Line 19: | Line 19: | 
|  | |   |  | |   | 
|  | * 0.7 for wood based |  | * 0.7 for wood based | 
| − | * 0.4 for aggregate | + | * 0.4 for stone | 
|  | |- |  | |- | 
| − | | [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'') | + | | [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'') | 
|  | |   |  | |   | 
|  | * 300 mm to support turf grass (and accept only rainwater/roof runoff) |  | * 300 mm to support turf grass (and accept only rainwater/roof runoff) | 
| − | * 600 mm to support flowering [[perennials]] and decorative [[grasses]] | + | * 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]] | 
|  | * 1000 mm to support [[trees]] |  | * 1000 mm to support [[trees]] | 
| − | | 0.35 | + | | | 
|  | + | * 0.35 for Blend A - Drainage rate priority; | 
|  | + | * 0.4 for Blend B - Water quality treatment priority | 
|  | |- |  | |- | 
|  | | Pipe diameter reservoir |  | | Pipe diameter reservoir | 
| Line 36: | Line 38: | 
|  | | 0.4 |  | | 0.4 | 
|  | |} |  | |} | 
| − | 
 |  | 
| − | ==Calculate the maximum overall depth==
 |  |