| | Detention time | | Detention time |
| | A detention time of 24 hours should be targeted in all instances. Where this necessaitates a very low outflow, a [[Flow control#Vortex valve|vortex valve]] or similar is recommended over an orifice or pipe restiction. The detention time is approximated by the drawdown time. | | A detention time of 24 hours should be targeted in all instances. Where this necessaitates a very low outflow, a [[Flow control#Vortex valve|vortex valve]] or similar is recommended over an orifice or pipe restiction. The detention time is approximated by the drawdown time. |
| − | The drawdown time in the pond can be estimated using Equation 4.10. Equation 4.10 is the classic falling head orifice equation which assumes a constant pond surface area. This assumption is generally not valid, and a more accurate estimation can be made if Equation 4.10 is solved as a differential equation. This is easily done if the relationship between pond surface area and pond depth is approximated using a linear regression. | + | The drawdown time in the pond can be estimated using the classic falling head orifice equation which assumes a constant pond surface area<ref>Ontario Ministry of Environment. (2003). Stormwater Management Planning and Design Manual. Retrieved January 15, 2017, from https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design</ref>. This assumption is generally not valid, and a more accurate estimation can be made if the equation is solved as a differential equation. This is easily done if the relationship between pond surface area and pond depth is approximated using a linear regression. |
| | | | |
| | <math>A_O=\frac{2A_{P}}{t\ C(2g^{0.5})}\left ( h_{1}^{0.5}-h_{2}^{0.5} \right )</math> | | <math>A_O=\frac{2A_{P}}{t\ C(2g^{0.5})}\left ( h_{1}^{0.5}-h_{2}^{0.5} \right )</math> |
| | + | {{planlist|1=Where |
| | + | * t = Drawdown time (s) |
| | + | * A<sub>p</sub> = Surface area of the pond(m<sup>2</sup>) |
| | + | * C = Discharge coefficient (typically 0.63) |
| | + | * A<sub>O</sub> = Cross-sectional area of the orifice(m<sup>2</sup>) |
| | + | * g = Gravitational acceleration constant (9.81 m/s<sup>2</sup>) |
| | + | * h<sub>1</sub> = Starting water elevation above the orifice (m) |
| | + | * h<sub>2</sub> = Snding water elevation above the orifice (m)}} |
| | | | |
| − | t = start fraction 2 A subscript p over C A subscript o left-parenthesis 2 g right-parenthesis superscript 0 point 5 end fraction left-parenthesis h subscript 1 superscript 0 point 5 minus h subscript 2 superscript 0 point 5 right-parenthesis
| |
| | | | |
| − | or if a relationship between Ap and h is known (i.e., A = C2h + C3)
| |
| | | | |
| − | t = start fraction 0 point 66 C subscript 2 h superscript 1 point 5 + 2 C subscript 3 h superscript 0 point 5 over 2 point 75 A subscript o end fraction
| |
| − |
| |
| − | where:
| |
| − |
| |
| − | t
| |
| − | drawdown time in seconds
| |
| − | Ap
| |
| − | surface area of the pond(m²)
| |
| − | C
| |
| − | discharge coefficient (typically 0.63)
| |
| − | A0
| |
| − | cross-sectional area of the orifice(m²)
| |
| − | g
| |
| − | gravitational acceleration constant (9.81,/s2)
| |
| − | h1
| |
| − | starting water elevation above the orifice (m)
| |
| − | h2
| |
| − | ending water elevation above the orifice (m)
| |
| | C2 | | C2 |
| | slope coefficient from the area-depth linear regression | | slope coefficient from the area-depth linear regression |
| | C3 | | C3 |
| | intercept from the area-depth linear regression | | intercept from the area-depth linear regression |
| − |
| |
| − | <ref>Ontario Ministry of Environment. (2003). Stormwater Management Planning and Design Manual. Retrieved January 15, 2017, from https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design</ref>
| |
| | | | |