| Line 53: | 
Line 53: | 
|   | *Begin the drainage time calculation by dividing the area of the practice (''A<sub>p</sub>'') by the perimeter (''P'').  |   | *Begin the drainage time calculation by dividing the area of the practice (''A<sub>p</sub>'') by the perimeter (''P'').  | 
|   | *To estimate the time (''t'') to fully drain the facility:    |   | *To estimate the time (''t'') to fully drain the facility:    | 
| − | :<math>t=\frac{V_{R}A_{p}}{f'P}ln\left [ \frac{\left (d+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>  | + | :<math>t=\frac{V_{R}A_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>  | 
|   | {{Plainlist|1=Where:  |   | {{Plainlist|1=Where:  | 
|   | *''V<sub>R</sub>'' is the void ratio of the media,    |   | *''V<sub>R</sub>'' is the void ratio of the media,    | 
| Line 59: | 
Line 59: | 
|   | *''f''' is the design infiltration rate (mm/hr),    |   | *''f''' is the design infiltration rate (mm/hr),    | 
|   | *''P'' is the perimeter of the practice (m), and  |   | *''P'' is the perimeter of the practice (m), and  | 
| − | *''d'' is the total depth of the practice, including the ponding zone (m).}}  | + | *''d<sub>T</sub>'' is the total depth of the practice, including the ponding zone (m).}}  | 
|   |  |   |  | 
|   | This 3 dimensional equation makes use of the hydraulic radius (''A<sub>p</sub>''/''P''), where ''P'' is the perimeter (m) of the facility. <br>  |   | This 3 dimensional equation makes use of the hydraulic radius (''A<sub>p</sub>''/''P''), where ''P'' is the perimeter (m) of the facility. <br>  |