From LID SWM Planning and Design Guide
		
		
		
		
		Jump to navigation
		Jump to search
		
Specifications for pervious concrete, porous asphalt, and permeable pavers
| Material | Specification | Quantity | 
| Pervious concrete | NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles.28 day compressive strength = 5.5 to 20 MPa.Porosity between 14% to 31%.Permeability = 900 to 21,500 mm/hr.Proprietary pre-cast slabs meeting required specifications are also available.
 | Thickness will range from 100 mm - 150 mm depending on the expected loads. | 
| Porous asphalt | Open-graded asphalt mix with a minimum porosity of 16%.Polymers can be added to provide additional strength to heavy loads.The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt.
 | Thickness will range from 50 mm - 100 mm depending on the expected loads. | 
| Permeable Interlocking Pacements | Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area.ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB).For narrow joint pavers, a smaller sized aggregate may be used.  Narrow joints are required where pavement must be AODA compliant.
 | For vehicle applications the minimum paver thickness is 80 mmFor pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm.
 |