| Line 2: | Line 2: | 
|  | [[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]] |  | [[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]] | 
|  | ===Simple=== |  | ===Simple=== | 
| − | {{plainlist| | + | {{textbox|{{plainlist| | 
|  | *Five percent of the average annual yield can be estimated: |  | *Five percent of the average annual yield can be estimated: | 
|  | *<strong>Y<sub>0.05</sub>=  A × C<sub>vol, A</sub> × R<sub>a</sub> × e × 0.05</strong> |  | *<strong>Y<sub>0.05</sub>=  A × C<sub>vol, A</sub> × R<sub>a</sub> × e × 0.05</strong> | 
| Line 10: | Line 10: | 
|  | *R<sub>a</sub> =  The average annual rainfall depth (mm) |  | *R<sub>a</sub> =  The average annual rainfall depth (mm) | 
|  | *e = The efficiency of the pre-storage filter |  | *e = The efficiency of the pre-storage filter | 
| − | }} | + | }}}} | 
|  |  |  |  | 
|  | Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information. |  | Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information. | 
|  | In a study of three sites in Ontario, STEP found the annual C<sub>vol, A</sub> of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and number of overflow events.<br> |  | In a study of three sites in Ontario, STEP found the annual C<sub>vol, A</sub> of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and number of overflow events.<br> | 
|  |  |  |  | 
| − | {{plainlist| | + | {{textbox|{{plainlist| | 
|  | *Five percent of the average annual demand (D<sub>0.05</sub>) can be estimated: |  | *Five percent of the average annual demand (D<sub>0.05</sub>) can be estimated: | 
| − | *<strong>D<sub>0.05</sub> =  P<sub>d</sub> × n × 18.25</strong> | + | *<strong>D<sub>0.05</sub> = P<sub>d</sub> × n × 18.25</strong> | 
| − | *D<sub>0.05</sub> = Five percent of the average annual demand (L) | + | *D<sub>0.05</sub> = Five percent of the average annual demand (L) | 
| − | *P<sub>d</sub> = The daily demand per person (L) | + | *P<sub>d</sub> = The daily demand per person (L) | 
| − | *n = The number of occupants}} | + | *n = The number of occupants}}}} | 
|  |  |  |  | 
|  | Then the following calculations are based upon two criteria: |  | Then the following calculations are based upon two criteria: |