| Line 15: |
Line 15: |
| | !style="background: cyan; color: black"|Wellhead Protection Area<ref>|Time-of-travel within wellhead protection areas</ref> | | !style="background: cyan; color: black"|Wellhead Protection Area<ref>|Time-of-travel within wellhead protection areas</ref> |
| | |- | | |- |
| − | | + | !style="background: #FFFDF5; color: black"|Rain Barrel |
| − | !Rain Barrel | |
| | !Not applicable | | !Not applicable |
| | !|[5 to 50 m<sup>2</sup>]||Not applicable||1||0||NA||Yes||None||None||None | | !|[5 to 50 m<sup>2</sup>]||Not applicable||1||0||NA||Yes||None||None||None |
| | |- | | |- |
| − | !Cistern | + | !style="background: #FFFDF5; color: black: black"|Cistern |
| | !Not applicable | | !Not applicable |
| | !|1:1||Not applicable||0||0||0||Yes||None||None||None | | !|1:1||Not applicable||0||0||0||Yes||None||None||None |
| | | | |
| | |- | | |- |
| − | !Roof Downspout Disconnection | + | !style="background: #FFFDF5; color: black"|Roof Downspout Disconnection |
| | !Not applicable | | !Not applicable |
| | !|[5 to 100 m<sup>2</sup>]||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||None||None | | !|[5 to 100 m<sup>2</sup>]||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||None||None |
| | |- | | |- |
| − | !Soakaway, Infiltration Trench or Chamber | + | !style="background: #FFFDF5; color: black"|Soakaway, Infiltration Trench or Chamber |
| | !1 | | !1 |
| | !|5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr | | !|5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr |
| | |- | | |- |
| − | !Bioretention | + | !style="background: #FFFDF5; color: black"|Bioretention |
| | !1 | | !1 |
| | !|5:1 to 15:1||Underdrain required<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr | | !|5:1 to 15:1||Underdrain required<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr |
| | |- | | |- |
| − | !Biofilter (Filtration only Bioretention Design) | + | !style="background: #FFFDF5; color: black"|Biofilter (Filtration only Bioretention Design) |
| | !Not applicable | | !Not applicable |
| | !|5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||None||None | | !|5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||None||None |
| | |- | | |- |
| − | !Vegetated Filter Strip | + | !style="background: #FFFDF5; color: black"|Vegetated Filter Strip |
| | !1 | | !1 |
| | !|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||None||None | | !|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||None||None |
| | |- | | |- |
| − | !Permeable Pavement | + | !style="background: #FFFDF5; color: black"|Permeable Pavement |
| | !1 | | !1 |
| | !|1:1 to 1.2:1||Underdrain Required <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr | | !|1:1 to 1.2:1||Underdrain Required <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr |
| | |- | | |- |
| − | !Enhanced Grass Swale | + | !style="background:#FFFDF5; color: black"|Enhanced Grass Swale |
| | !1 | | !1 |
| | !|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||1 m||None | | !|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||1 m||None |
| | |- | | |- |
| − | !Dry Swale (Bioswale) | + | !style="background: #FFFDF5; color: black"|Dry Swale (Bioswale) |
| | !1 | | !1 |
| | !|5:1 to 15:1||Underdrain Required <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||1 m||2 Yr | | !|5:1 to 15:1||Underdrain Required <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||1 m||2 Yr |
| | |- | | |- |
| − | !Perforated Pipe System | + | !style="background: #FFFDF5; color: black"|Perforated Pipe System |
| | !1 | | !1 |
| | !|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr | | !|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr |
| | |} | | |} |